SDC 2002
4.4 Film Menu
4-101
Operating Instructions - Rev. 1 / 6.2003
Fixed masking - coefficients, 1, 3, 5, 8, and 9 for TAF (Telecine Analysis Film) optimized
Item Matrix Name
(Filter)
Masking Coefficient Kodak Film Type
1 TCNEXR1
(Filter Color)
Color Negative TAF log. masking
R’ = 0.90 R + 0.05 G + 0.05 B
G’ = 0.00 R 1.05 G - 0.05 B
B’ = 0.00 R 0.05 G + 0.95 B
5279
2* TCN5279
(Filter Color)
Color Negativ TAF log masking
R’ = 0.85 R + 0.05 G + 0.10 B
G’ = - 0.05 R 1.05 G - 0.00 B
B’ = 0.10 R - 0.20 G + 1.10 B
5279
3 TPT5600
(Filter Primetime)
Primetime Negative TAF log. masking
R’ = 1.14 R - 0.13 G - 0.01 B
G’ = 0.00 R 1.04 G - 0.04 B
B’ = 0.04 R + 0.16 G + 0.80 B
5600
4* TPN5600
(Filter Primetime)
Primetime Negativ TAF log masking
R’ = 1.00 R - 0.03 G + 0.03 B
G’ = - 0.03 R 1.08 G - 0.05 B
B’ = 0.17 R 0.03 G + 0.80 B
5600
5 KIM5244
(Filter Intermediate)
Intermediate Positive Normal log. masking
(Not TAF, but film scenes optimized)
R’ = 1.05 R - 0.05 G 0.00 B
G’ = - 0.05 R + 1.10 G - 0.05 B
B’ = 0.02 R + 0.04 G + 0.94 B
5244
6* TIP5244
(Filter Intermediate)
Intermediate Positive TAF log masking
R’ = 0.92 R - 0.00 G + 0.08 B
G’ = -0.02 R + 1.00 G + 0.02 B
B’ = 0.12 R - 0.12 G + 1.00. B
5244
7 TIM5244
(Filter Intermediate)
Intermediate Positive TAF log. masking
R’ = 0.94 R + 0.05 G + 0.01 B
G’ = 0.05 R + 1.09 G - 0.14 B
B’ = 0.02 R + 0.04 G + 0.94 B
5244
8 TCP5285
(Filter Print)
Print Low Contrast Positive TAF log. masking
R’ = 1.00 R - 0.06 G + 0.06 B
G’ = - 0.05 R + 1.11 G - 0.06 B
B’ = 0.00 R - 0.08 G + 1.08 B
5285
9 TCPLIMX
(Filter Print)
Print Low Contrast Positive TAF linear matrix
R’ = 0.98 R - 0.03 G + 0.05 B
G’ = - 0.05 R + 1.10 G - 0.05 B
B’ = 0.00 R - 0.05 G + 1.05 B
5285
10* TCP5381
(Filter Print)
Print Positive TAF log masking
R’ = 0.97 R - 0.02 G + 0.05 B
G’ = - 0.13 R +1.20 G - 0.07 B
B’ = 0.03 R - 0.15 G +1.12 G
5381
* = Masking coefficient exclusive for SDC 2001 and SDC 2000 scanners from serial no.: 200 onwards.
Comentarios a estos manuales