4.9 Sprecial Menu SDC 2002
4-186
Operating Instructions - Rev. 1 / 6.2003
9. Hole Type
&
Reference
Hole
Hole Type
Selection of film type refence hole: Positive or Negative.
The system is able to handle type N (BH = Bell & Howell) and type P (KS =
Kodak System) perforation holes.
If pressed during measurements, operation is aborted and the system will be
re-initialized.
Ref. Hole
selection of reference perforation hole for a 35mm image
(1, 2, 3, 4; - 2= Mitchell hole)
4.9.3.1 STEADISCAN ADJUSTMENTS
During initialization the rulers left and right can be adjusted via horizontal
cursor keys. This may be necessary in the horizontal direction when another film
has been threaded.
First press “Adjusting” button
The rulers of the perf hole are displayed at the VGA monitor
2
Rulers
Bottom and top rulers are fixed symmetrically to the center of the displayed frame.
In case of local control via PC, press ENTER when finished and the new ruler posi-
tion will be stored on disk.
Ruler
Adjustment